Skip to content

RXDC Hypersphere

Innovative design, revolutionary ergonomics, advanced technology.

RXDC Hypersphere technology brings the best of DC X-ray units into your surgery.

Technical Specification

Hyper Ergonomy

HyperSphere technology gives the RXDC unit full rotation capability.

The tube revolves freely around the joint, allow it to reach practically any position, including the vertical. RXDC – HyperSphere technology also features an automatic touch-sensitive device for simple, efficient locking/release of the X-ray head tube so it can be repositioned effortlessly between one exposure and the next. Ergonomic zones on the sides of the head provide a firm grip for effective positioning.

Simple and immediate: Wireless

The wireless remote controller lets the user control the device (by communicating with the X-ray tube) while enjoying full freedom of movement.
Access to exposure programmes is provided via two simple settings.

The large display shows the sequential exposure monitor and the patient exposure dose; moreover, the controller has a wireless X-ray snapshot button. Wireless device control allows fast, easy installation: no fixed control panels are required, thus providing greater freedom when positioning the X-ray unit.

Hyper Performance MAXIMUM QUALITY

With a tiny focal spot of 0.4 mm (at 30 cm), RXDC – HyperSphere technology produces sharp images under any condition.

The tube head is now even more powerful as it operates at 70 kV, 8 mA. RXDC – HyperSphere technology gives your surgery the precision and quality of cuttingedge know-how.

MINIMUM DOSE

The constant potential high frequency (DC) generator reduces the most harmful low energy radiation that is characteristic of analogue (AC) generators: current is adjustable (from 8 mA to 4 mA), as are exposure times.

Moreover, the long cone (30 cm) with incorporated rectangular collimator reduces the exposed surface area. This maximises image quality and safeguards patient and worker health.

MULTI-MODE
Maximum flexibility to meet your diagnostic needs. Automatic parameter modulation ensures exposure power and time are always selected according to the patient’s build and the specific region of investigation.

SEQUENCED EXPOSURE

The dynamic service cycle allows uninterrupted use of the RXDC, as in the case of systematic examinations, and real-time monitoring of tube head temperature on the large wireless controller display.

COMPLETE EQUIPMENT SET

RXDC – HyperSphere technology features a 30 cm cone with a circular and rectangular collimator.

The rectangular collimator is ideal for reducing the X-ray dose administered to the patient as it limits the irradiated body area to the effective capture capacity of the sensor.

Hyper Ergonomy HyperSphere technology gives the RXDC unit full rotation capability. The tube revolves freely around the joint, allow it to reach practically any position, including the vertical. RXDC - HyperSphere technology also features an automatic touch-sensitive device for simple, efficient locking/release of the X-ray head tube so it can be repositioned effortlessly between one exposure and the next. Ergonomic zones on the sides of the head provide a firm grip for effective positioning. Simple and immediate: Wireless The wireless remote controller lets the user control the device (by communicating with the X-ray tube) while enjoying full freedom of movement. Access to exposure programmes is provided via two simple settings. The large display shows the sequential exposure monitor and the patient exposure dose; moreover, the controller has a wireless X-ray snapshot button. Wireless device control allows fast, easy installation: no fixed control panels are required, thus providing greater freedom when positioning the X-ray unit. Hyper Performance MAXIMUM QUALITY With a tiny focal spot of 0.4 mm (at 30 cm), RXDC - HyperSphere technology produces sharp images under any condition. The tube head is now even more powerful as it operates at 70 kV, 8 mA. RXDC - HyperSphere technology gives your surgery the precision and quality of cuttingedge know-how. MINIMUM DOSE The constant potential high frequency (DC) generator reduces the most harmful low energy radiation that is characteristic of analogue (AC) generators: current is adjustable (from 8 mA to 4 mA), as are exposure times. Moreover, the long cone (30 cm) with incorporated rectangular collimator reduces the exposed surface area. This maximises image quality and safeguards patient and worker health. MULTI-MODE Maximum flexibility to meet your diagnostic needs. Automatic parameter modulation ensures exposure power and time are always selected according to the patient’s build and the specific region of investigation. SEQUENCED EXPOSURE The dynamic service cycle allows uninterrupted use of the RXDC, as in the case of systematic examinations, and real-time monitoring of tube head temperature on the large wireless controller display. COMPLETE EQUIPMENT SET RXDC - HyperSphere technology features a 30 cm cone with a circular and rectangular collimator. The rectangular collimator is ideal for reducing the X-ray dose administered to the patient as it limits the irradiated body area to the effective capture capacity of the sensor.

Documents

RXDC Hypersphere

Options

Add to quote Cart